Normally Closed AC SSR

This is a Normally Closed PCB Mount SSR. That means when DC Control input is low, the triac is ON, the output passes the load current to turn on small heater-motor-lamp or a bigger contacter-drive etc.

NC AC Load SSR DC control

NC Solid State Relay or SSR

When input DC is high the output is OFF. This is also Optically Isolated from Mains. A Microcontroller output which is buffered by some driver can drive this relay. It is better that in big systems these SSR Modules can be on another PCB, to avoid mains wiring near Logic circuits. But this cannot be used for medical electronics, or critical applications. More reliability and visual isolation of voltages may be required for such equipment.

Tuesday, July 04, 2017

RTD Pt-100 Four Point Alarm

Here 4052 is used as an analog multiplexer, U3A TL062 opamp is wired as a 1mA Constant Current Source. It pumps 1mA into U2 4052 pin 13 X . Depending on BCD code on inputs A, B of 4052 the current is routed to any one of the four RTD 100E, whose one end is connected to X0-X3. The current then flows to GND thru the Platinum 100E resistance. The Y0-Y3 monitors the mV developed on RTD in tandem with X0-X3 positions. Like a ganged rotary switch. The Output mV at Y is the mV of Active Channel as selected by the BCD of 4029.

RTD Pt-100 Four Point Alarm - del90001

The BCD is provided by 4029 counter which is clocked by a 555. U5A cancels out the 100E mV (1mA * 100E) of a cold RTD and Amplifies the differential mV. This output of U5A is in proportion with measured temperature. U5B compares the mV that was obtained with a preset mV of POT1, which is a user setting called setpoint.

RTD Pt-100 Four Point Alarm
Pan and Zoom the Circuit for detailed Study here - Pt-100 RTD Four Point Alarm

The difference is amplified by U5B which is saturated by U3B comparator which adds a little hysteresis too. R7-C2 further dampen and slow the response. This finally drives Q2 to provide a Logic Signal indicating if temperature is below or above setpoint.

Four points in a Closed Loop Temperature Control System is Monitored and a Alarm set to go off when the temperature goes beyond the set limit.

Saturday, July 01, 2017

1 Hz or 1 PPS Crystal Clock Base

The CD4020BC, CD4060BC are 14-stage ripple carry binary counters, and the CD4040BC is a 12-stage ripple carry binary counter. The counters are advanced one count on the negative transition of each clock pulse. The counters are reset to the zero state by a logical "1" at the reset input independent of clock.

CD4040BC, 12-Stage Ripple Carry Binary Counters
CD4060BC, 14-Stage Ripple Carry Binary Counters

1 Hz or 1 PPS Crystal Clock Base

CD4060 - 14-Stage Ripple Carry Binary Counters
you can also use a crystal between pin 10 and 11 with two caps 22pF from 10, 11 to gnd and a 10M resistor between 10 and 11 in place of R C network for more precision.

Hobby DIY Electronics